at+keepalive?//querythekeepalivepacket
+KEEPALIVE:10,"ThisistheKeepAlivePacket"
OK
at+socketopen?//Sockettoconnectastateinquiry
OK
at+gprsconfig=1,"cmnet","wap","wap" //settinganorderforOpenATmodel;APN:cmnet,
username:wap,password:wap;
OK
at+clientconfig=1,"www..szelins.com/",80//setuptheclientserver:”
www..szelins.com”,port:80
OK
at+idletime=0//setuptoconnectofalways
online
OK
at+reginfo=0 //Regiftrysettingforeachpacketsentimmediatelyto
connect,closetheRegistrationinformationpacket
OK
at+keepalive=20,"ThisistheKeepAlivePacket!"//Setkeepalivepack etfor20
seconds,Says:"ThisistheKeepAlivePacket!"
OK
at+dtuid=32165498721//settheDTUID,in11figures
OK
at+datamode=0
OK
at+cfun=1
//RestarttheDTU
OK
at+dataopen//DATAtransmission
OK
……
……
……(SendingDATA)
……
……//+++delay1secnod,returntothecommandmode
OK
OK
at+socketclose//closethedatatransmission